LCR Meters 
Wayne Kerr - 6500 series 

The new 6500P range offers the widest range of HF LCR meters currently available. The corresponding price range means that users will be able to select a model which meets their requirements and is priced accordingly.
Engineers need to evaluate component characteristics at high frequencies with very high levels of accuracy. The 65120B 120MHz Precision Impedance Analyzer is therefore ideal for many demanding tasks, combining accuracy and ease of use at an affordable price. If a frequency range up to 120MHz is not required then the other models are available in this range.
 

Wayne Kerr - 4300 series 

The 4300 range not only offers all the parameters normally found in a standard LCR meter, but it also measures many more to give a truly versatile instrument. RS232 or GPIB interface is included as standard and it can be used with the full range of Wayne Kerr accessories for even more flexibility. 
 



TTi - LCR 400 

The LCR400 provides the performance and facilities required for precision component measurement at a price not far above that of a hand-held unit. The LCR400 is a low-cost precision LCR bridge intended for use within component inspection, laboratories and production facilities.

  • 0.1% basic measurement accuracy
  • three test frequencies of 100Hz, 1kHz and 10kHz
  • automatic component recognition
  • built-in 4 terminal component fixture
  • dual 5 digit high brightness displays
  • limits comparator with multiple pass and fail bins
  • RS-232 interface for PC connectivity, optional PC software



IET Labs - 7600

The 7600 Plus LCR Meter performs precision impedance measurements over a frequency range of 10 Hz to 2 MHz. The LCR Meter can measure 14 different impedance parameters with 0.05% accuracy, meeting today’s requirements for component and material testing. The ease of use and user-friendly menu programming makes the 7600 Plus ideal for applications in product development, incoming inspections, or production line testing.
Swept Measurements: Fast and accurate swept parameter measurements, graphical or tabular, for verification of component and material response to changes in ac test frequency, ac test voltage or ac test current, without the need for complex programming or an external controller

  • Measures 14 impedance parameters (2 simultaneously)
  • 0.05% basic measurement accuracy
  • Programmable frequencies from 10 Hz to 2 MHz
  • AC test voltage programmable from 20 mV to 5 V
  • DC bias voltage: 2 V internal or 0 to 200 V external
  • Fast measurement speeds up to 120/Second
  • Automatic open/short compensation eliminates connection errors
  • High resolution LCD with 7 digit display
  • 14 hi/lo sorting bins for pass/fail testing
  • Now manufactured by IET Labs
  • RS-232, USB host port, printer, PLC interfaces all standard, (IEEE-488 adapter optional)
  • Results displayed as deviation or % deviation from a nominal value
  • Internal storage and recall of test setups
  • Ability to automatically perform 6 unique tests in sequence
  • Keypad lockout prevents changes to the test setup
  • On site calibration with 7000-09 Calibration Kit
  • Programmable average and delay times

IET Labs - 1920

The 1920 1 MHz LCR Meter is the most popular and designed to perform capacitance and impedance measurements on a variety of electronic components and materials over a frequency range from 20 Hz to 1 MHz. The 1920 features programmable bias voltage from 1 mV to 2 V for biasing capacitors and other semiconductor devices during measurements.
The 1910 Inductance Analyzer has the same feature as the 1920, with the bias voltage feature being replace by a programmable bias current of up to 1 A. The bias current features makes the 1910 designed to perform inductance and impedance measurements on coils and wire wound devices over a frequency range from 20 Hz to 1 MHz.
Emphasis has been placed on ease of use through menu programming, and fast accurate production testing via its remote control capability with RS-232, handler and GPIB interfaces.

15 Different Impedance Parameters/20 Total Parameters 
Measure and display any two parameters simultaneously, to achieve coverage and flexibility not previously available.
Automatic Test Sequencing 
Run up to six different tests in sequence with a single push of the start button. Each test can have different conditions and limits.
Program Storage Test setups can be stored and recalled from internal memory. The front panel can be locked out, with password protection, to ensure procedures are run the same way every time.
Configure instrument and log results to PC IET offers a Window based program that can be downloaded for
free. 1900 Virtual Front Panel

  • 20 Hz to 1 MHz frequency range (27,000 possible test frequencies)
  • 0.1% basic measurement accuracy
  • Measures 15 impedance parameters, dc resistance, voltage and current monitor
  • Wide measurement range with 5 digit measurement resolution
  • Four-terminal Kelvin connections to maintain measurement integrity
  • AC test voltage programmable from 20 mV to 1V

IET Labs - DE-6000

This handheld LCR meter can transfer data to a PC via a optional, fully isolated, optical IR-USB interface. It also features a Sorting mode, allowing users to quickly sort components. The DE-6000 handheld LCR Meter has automatic impedance selection. This allows the user to measure the L/C/R components in Auto LCR mode without having to select the type of measurement.
To accommodate various test requirements, the DE-6000 handheld LCR Meter offers selectable test frequencies: 100 Hz / 120 Hz  / 1 kHz / 10 kHz / 100 kHz.
The LCR Meter is powered by a standard 9V battery. For additional convenience, it may also use an optional ac adapter
(DE-6000-AC). To transfer data to a PC, the LCR Meter comes with a built-in IR interface.IET offers an optional Data Transfer Kit
(
DE-6000-DTK). This kit includes: IR-USB interface adapter, a USB cable, and a CD with software for the PC.

The DE-6000 is a high-performance handheld LCR meter that is full-featured yet cost effective. The 0.2% basic accuracy and optional USB interface for data transfer separates the DE-6000 from other handheld LCR meters. It measures:
     Ls/Lp -- Series and parallel inductance
     Cs/Cp -- Series and parallel capacitance
     Rs/Rp -- Series and parallel resistance (ac)
     Rdc/Rp -- Series and parallel resistance (dc)
     ESR/Rp -- Series and parallel equivalent resistance
     D -- Dissipation factor
     Q -- Quality factor
     Θ -- Phase angle